A Printable, Flexible, Lightweight Temperature Sensor
November 16, 2015 | University of TokyoEstimated reading time: 2 minutes
A University of Tokyo research group has developed a flexible, lightweight sensor that responds rapidly to tiny thermal changes in the range of human body temperature. This sensor is expected to find healthcare and welfare applications in devices for monitoring body temperature, for example of newborn infants or of patients in intensive care settings.
Flexible and wearable devices are increasingly being developed for healthcare and other applications where temperature and other sensors are integrated to provide feedback on patient health and wellbeing. Body temperature is a fundamental measurement and many low-cost flexible temperature sensors have been demonstrated, but devices developed to date require external circuitry to amplify the signal to allow accurate temperature measurement.
In their latest research, Professor Takao Someya and Dr. Tomoyuki Yokota's research group at the Graduate School of Engineering have developed a new printable, flexible, lightweight temperature sensor that shows a very high change in electrical resistance of up to 100,000 times over a range of just five degrees centigrade, allowing accurate temperature measurement without additional complicated display circuitry.
The key to the new sensor is the ability to precisely control the target temperature of the sensors. The sensor is composed of graphite and a semicrystalline acrylate polymer formed of two monomers, molecules that bond together to form a polymer chain. The target temperature range at which the sensor is most precise can be selected simply by altering the proportions of the two monomers. The research group achieved target temperatures between 25 and 50 degrees centigrade, a range which includes average human body temperature, and simultaneously realizing response times of less than 100 milliseconds and a temperature sensitivity of 0.02 degrees centigrade. The device was also stable even under physiological conditions, providing repeated readings up to 1,800 times.
The research group tested their new sensor by printing a flexible thermal monitoring device which was placed directly on the lung of a rat to measure lung temperature. The device successfully measured cyclic changes in lung temperature of just 0.1 degrees centigrade as the animal breathed, demonstrating its utility as a sensor for monitoring body vital signs in physiological (internal) settings.
"By printing an array of these sensors it is possible to measure surface temperature over a large area," says Professor Someya. He continues, "This sensor array can be attached to biological tissue such as the skin for precise monitoring in medical applications. Because the huge response of the sensor to temperature change allows us to simplify the circuitry, we could print our sensors onto adhesive plasters that could then monitor body temperature. For example, a plaster applied directly to a wound or after surgery could provide warning of infection by detecting local changes in temperature due to inflammation."
Other possible applications include wearable electronic apparel, where the sensor could be applied beneath fabric to measure temperature during sporting and other activities.
Suggested Items
New Book on Low-temperature Soldering Now Available
04/17/2024 | I-Connect007I-Connect007 is pleased to announce that The Printed Circuit Assembler’s Guide to… Low-temperature Soldering, Vol. 2, by subject matter experts at MacDermid Alpha Electronics Solutions, is now available for download.
The Chemical Connection: Reducing Etch System Water Usage, Part 1
04/05/2024 | Don Ball -- Column: The Chemical ConnectionWater conservation has become an important component of the overall system design for most manufacturing operations today. Changing climate conditions and increasing populations are beginning to strain the freshwater supplies in many areas of the country. As a result, as equipment suppliers, we see an increasing number of requests for options that reduce water usage in proposed wet processing systems. Etching systems tend to use more water because of the need for close temperature control to maintain steady etch rates and the rinsing requirements for complete removal of corrosive etchants from the surface of the product before the next process step. This column contains some simple suggestions for reducing water usage in etch systems that won’t strain the budget too much.
Indium’s Sze Pei Lim to Present on Semiconductor Packaging at ICEP Japan
04/02/2024 | Indium CorporationIndium Corporation’s Senior Global Product Manager for Semiconductor and Advanced Materials, Sze Pei Lim, is scheduled to present at the International Conference on Electronics Packaging (ICEP 2024).
Nihon Superior Sets New Standards in Lead-Free Soldering Technology at APEX 2024
03/13/2024 | PVANihon Superior Co. Ltd., an advanced joining material supplier, will exhibit in Booth 1325 during the 2024 IPC APEX EXPO, scheduled to take place April 9-11, 2024 at the Anaheim Convention Center in California.
Indium Corporation to Showcase Proven EV Products and High-Reliability Alloys at Productronica China
02/28/2024 | Indium CorporationAs a materials pioneer and trusted partner in electric vehicle (EV) and e-Mobility manufacturing, Indium Corporation is proud to showcase its high-reliability alloys and soldering solutions at Productronica China, March 20-22, in Shanghai.