All About Flex: Considerations for Impedance Control in Flexible Circuits
August 4, 2016 | Dave Becker, All FlexEstimated reading time: 4 minutes
Impedance can be thought of as a system’s opposition to alternating or pulsing electronic current. The unit of measurement is ohms, the same unit of measurement in a direct current system. However, the components for calculating impedance are much more complex than DC resistance. For a direct current system, the resistance is related to the relative ease with which electrons can flow through the material. Ohm’s law describes a fairly straightforward relationship between current and voltage (V=IR or R=V/I) where R is a constant number for any given material. Impedance is characterized by the equation including the DC resistance but also includes another component called reactance. Reactance is the ability of the system to store and release energy as current or voltage alternates. The equation for impedance is Z=R +iX, where iX is the reactance component. The reactance is a function of the capacitance of the system and the frequency of the alternating or pulsing current.
Why is impedance important?
Impedance is important for high-speed electronics. When frequencies become 200 MHz or higher, the impedance and impedance consistency becomes a significant factor in the system performance. During the last 20 years, electronic packages have become smaller, denser and faster. It is estimated that in 2000, only a small percentage of PCB and flexible printed circuit (FPCB) designs had an impedance requirement. As higher and higher frequencies continue their relentless march, impedance requirements today have become much more prevalent and important.
In a direct current system, when two components of different resistance are connected in series, the system resistance is simply equal to the two components added together (R1 +R2). The flow of the electrons is homogenous. The analogy is a garden hose where the flow of the water is the same throughout the hose.
In high-speed electronics, impedance does NOT behave the same way. High speed signals are like separate pulses propagating through the system. The current and magnetic pulses are affected by the impedance. When the pulses encounter a node of mismatched impedance, a flux of energy is induced which creates competing signals that can interfere with the main signal. The result is power loss and distortion of the signal.
Many nodes of mismatched impedance can occur within a PCB system as attached components, conductor width, conductor spacing and dielectric thicknesses change. One way to deal with this issue is to isolate the signal traces so that the dielectric and geometries are identical throughout the signal path. This is called controlled impedance. In flexible circuits, there are two categories of designs that are typically used for controlled impedance: microstrip and stripline (Figure 1). Within the categories one can have single-ended transmission lines and differential pair transmission lines.
Figure 1: Designs for controlled impedance.
In both designs, the impedance is affected by the following:
- Dielectric constant (Dk) of the materials
- The DC resistance of the signal line
- Distance between the signal lines and ground planes or signal line pairs
Page 1 of 2
Suggested Items
Trouble in Your Tank: Supporting IC Substrates and Advanced Packaging, Part 5
03/19/2024 | Michael Carano -- Column: Trouble in Your TankDirect metallization systems based on conductive graphite or carbon dispersion are quickly gaining acceptance worldwide. Indeed, the environmental and productivity gains one can achieve with these processes are outstanding. In today’s highly competitive and litigious environment, direct metallization reduces costs associated with compliance, waste treatment, and legal issues related to chemical exposure. What makes these processes leaders in the direct metallization space?
AT&S Shines with Purest Copper on World Recycling Day
03/18/2024 | AT&SThe Styrian microelectronics specialist AT&S is taking World Recycling Day as an opportunity to review the progress that has been made in recent months at its sites around the world in terms of the efficient use of resources:
Matrix to Exhibit at IPC APEX EXPO 2024 in Anaheim, CA
03/05/2024 | MatrixMatrix will be exhibiting at IPC APEX EXPO 2024, to be held on April 9-12, 2024, at the Anaheim Convention Center, Anaheim, CA.
The Chemical Connection: Getting to Know Your Vendor
02/16/2024 | Don Ball -- Column: The Chemical ConnectionAfter working for a capital equipment supplier for almost 50 years, I’ve found that the most important part of getting to know your vendor is good communication among all parties. While contact between fabricators of a constantly changing product line and the designers of those products may occur daily or weekly, conversations between you and your equipment supplier may be years apart. That lengthy gap often means that previous contacts may have been promoted, retired, or moved on to other opportunities. You may have also migrated to a new supplier with whom you have little or no history. In either case, you will be interacting with someone you are unfamiliar with (as they are with you). Therefore, it is essential for both sides to communicate clearly so expectations will align.
EIPC Winter Conference 2024, Day 2: A Closer Look at Global Trends
02/14/2024 | Pete Starkey, I-Connect007The opening session of the second day’s conference proceedings focused on global PCB trends and was introduced and moderated by Dr. Michele Stampanoni, vice president of strategic sales and business development at Cicor Group in Switzerland. He opened the session with Dr. Hayao Nakahara’s knowledgeable and enlightening video presentation on the IC substrates industry.