While copper may not rank the best in any one of the above criteria, it probably has the best overall rating.

Electrical Conductivity

The following chart[1] ranks the common metals by conductivity:

Flexible_Circuitry1.jpgCopper is the second-most conductive metal (in pure form). The copper used on flexible circuits can be formed by a number of methods such as electro-deposition (ED), rolling/annealing, or a combination of the two. The conductivity of copper by volume on a flexible circuit is not exactly the same as pure copper, but it is quite close.

Flexible_Circuitry2.jpgThermal Conductivity

Thermal conductivity is highly related to electrical conductivity. Thermal conducting properties are very important for a number of applications, particularly when heat dissipation is critical.

As can be seen from the chart above[2], copper is an excellent thermal conductor, relative to the other common metals.

Cost

Copper is one of the lowest cost metals that are viable for electronic applications. The following chart below shows typical costs by weight, and more importantly by volume.

Spot prices of metal costs can vary significantly from day to day. The costs above are based on one snapshot in time, but one can see that the relative differences are significant. The costs shown are based on spot prices and do not include the costs for processing the metals for electronic fabrication. Aluminum is very inexpensive relative to other metals, but copper is significantly cheaper than gold or silver.

Availability

Availability or abundance of supply tends to be inversely proportional to the cost. Copper is considered plentiful and is stated to have a 40-year supply based on reserves and 200 years based on resources.  The difference between reserve and resource is: Reserves are based on viable deposits that have been discovered and are either being mined or are deemed profitable to mine; Resources are based on potentially profitable discovered deposits and undiscovered deposits predicted by geological surveys[3]

Flexible_Circuitry3.jpg

Flexible_Circuitry4.jpgCorrosion Resistance

Corrosion resistance in any environment depends on the chemical exposure. The following chart[4] rates common metals by activity, which is an indicator of the likelihood of corrosion in the presence of moisture and ionic contamination.                                     

Copper is in the middle of the pack on the galvanic scale and is often treated, coated or plated to dramatically retard corrosion.

Flexible_Circuitry5.jpgFlexibility

An indicator of flexibility is the Young’s Modulus of Elasticity. This measurement relates to the amount of force it takes to change the elongation direction. The lower the number, the easier it will “stretch.” The chart below shows the Modulus numbers of the more common metals.                           

It is important to note that the flexibility of copper substrates used in circuit fabrication is highly related to the processing method used to create the foil. Rolled annealed copper goes through a series of rolling steps that elongates the grain, giving it a higher degree of flexibility. Even ED copper, which forms metal foil by electroplating copper onto a rotating stainless steel drum, is quite flexible and suitable for many flex-to-install applications. But the overwhelming favorite copper for flexible circuitry is rolled annealed. It is comparable in cost and offers the insurance of being the most robust with flexibility.

Another critical consideration is ease of processing. Copper is incredibly versatile and works well with a diverse set of circuit fabrication steps including electroplating, immersion and electroless plating, etching and soldering. While many of these processes have been designed around copper, this metal has remained the stand-alone workhorse for more than 50 years of printed circuit board processing.

References

1. www.metaldetectingworld.com.

2. www.tibtech.com

3. copperalliance.org

4. inspectapedia.com 

Dave Becker is vice president of sales and marketing at All Flex Flexible Circuits LLC.

Share

Print


Suggested Items

EIPC Technical Snapshot: Automotive Technology

10/19/2020 | Pete Starkey, I-Connect007
Although current circumstances have forced the postponement of its live conferences, seminars, and workshops, EIPC continues to provide a platform for the exchange and dissemination of the latest knowledge and technical information to the European interconnection and packaging industry. Pete Starkey details how its current series of technical snapshots, delivered in webinar format, address technology challenges facing the automotive, telecom, and high-speed sectors of the industry.

Just Ask John Mitchell: The Exclusive Compilation

10/05/2020 | I-Connect007 Editorial Team
We asked for you to send in your questions for IPC President and CEO John Mitchell, and you took us up on it! We know you all enjoyed reading these questions and answers, so we’ve compiled all of them into one article for easy reference. We hope you enjoy having another bite at the apple. And if you’d like to hear more from John Mitchell, view his column series “One World, One Industry.”

I-Connect007 Editor's Choice: Five Must-Reads for the Week

10/02/2020 | Nolan Johnson, I-Connect007
Most all the action this week involved the STMA International Conference and Exposition. I-Connect007’s Real Time with… video interviews generally led the way for views and clicks. In each item, the intent was to make things better in some fashion. Whether it was pivoting on trade show delivery, optimizing the metalization process in the fab, adding more AI to manufacturing capital equipment, unifying and furthering the concept of the digital twin concept, or responding to company growth by upgrading systems with the help the equipment manufacturers, all these news items speak to being adaptable and forward-thinking.



Copyright © 2020 I-Connect007. All rights reserved.